This manual provides essential guidance for installing, operating, and maintaining the Mira Advance ATL Thermostatic Shower, ensuring safe and optimal use of its advanced features.
1.1 Overview of the Mira Advance ATL Thermostatic Shower
The Mira Advance ATL Thermostatic Shower is a high-performance, temperature-controlled shower system designed for comfort and safety. It features an adjustable temperature limit and a thermostatic valve to ensure consistent water temperature. The shower is suitable for mains-fed cold water systems and includes advanced safety features like anti-scald protection. The system is equipped with a drain pump for efficient water drainage and diagnostic lights for troubleshooting. Its sleek design and user-friendly interface make it ideal for modern bathrooms. The shower is designed for indoor use only and requires proper installation as outlined in the manual to ensure optimal performance and safety.
1.2 Importance of Following the Manual Instructions
Adhering to the Mira Advance ATL Thermostatic Manual is crucial for ensuring safety, optimal performance, and compliance with regulations. The manual provides detailed guidelines to prevent accidents, such as scalding, and ensures proper installation and maintenance. Failure to follow instructions may result in voiding the warranty or causing system malfunctions. It emphasizes isolating electrical and water supplies before installation and adjusting temperature limits to prevent overheating. By following the manual, users can troubleshoot common issues effectively and maintain the shower’s advanced features. Proper adherence ensures a safe and enjoyable showering experience while prolonging the product’s lifespan.
Installation Instructions
Isolate water and electrical supplies before starting; Connect pipes and wiring as per the manual. Ensure all safety measures are in place for a secure setup.
2.1 Pre-Installation Requirements and Safety Precautions
Before installation, ensure the water supply is turned off and electrical power is isolated. Verify compatibility with mains-fed cold water systems only. Check for necessary tools and parts. Follow all warnings and cautions in the guide to avoid hazards. Proper ventilation and drainage setup are crucial. Ensure the installer is qualified and adheres to safety standards. Familiarize yourself with the manual to prevent errors. Safety precautions include avoiding over-tightening connections and ensuring correct pump configuration. Always refer to the troubleshooting section if issues arise during setup.
2.2 Step-by-Step Installation Process
Begin by mounting the shower unit securely to the wall, ensuring it is level and properly aligned. Connect the drain pump according to the manufacturers’ instructions, making sure it is compatible with the Mira Advance ATL. Next, attach the water supply pipes, avoiding over-tightening to prevent damage. Install the electrical connections, ensuring all wires are securely fastened and comply with safety standards. Finally, test the system by turning on the water and power supplies, checking for leaks and proper functionality. Always follow the specific guidelines outlined in the manual for precise configuration and setup.
2.3 Connecting Electrical and Water Supplies
Ensure the water supply is mains-fed cold water only, as specified. Isolate both water and electrical supplies before starting connections. Attach the shower’s inlet pipes to the water supply, using appropriate adapters if necessary. For electrical connections, wire the live, neutral, and earth terminals according to the manual. Secure all connections tightly but avoid over-tightening. Once connected, slowly turn on the water supply and inspect for leaks. Finally, restore power and test the shower’s operation. Always follow safety guidelines and refer to the manual for detailed wiring and plumbing instructions to ensure a safe and correct installation.
2.4 Drain Pump Setup and Configuration
Begin by identifying the Whale InstantMatch pump type number for compatibility with the Mira Advance ATL. Place the pump on a level surface, ensuring it is securely fastened to prevent movement. Connect the shower waste hose to the pump’s inlet and the discharge hose to the pump’s outlet. Ensure all connections are tight to avoid leaks. Plug in the pump and connect it to the shower’s electrical system according to the manual. Test the pump by running water through the shower to confirm proper function. Refer to the Whale Shower drain pump instructions for detailed configuration and troubleshooting guidance.
Operating the Mira Advance ATL Thermostatic Shower
Learn to operate the Mira Advance ATL Thermostatic Shower by adjusting temperature settings and utilizing safety features like anti-scald protection. Refer to the manual for detailed guidance.
3.1 Understanding Temperature Control and Limits
The Mira Advance ATL Thermostatic Shower features precise temperature control, ensuring a safe and comfortable showering experience. The thermostatic valve automatically maintains your desired temperature, even with fluctuations in water pressure or flow. The system includes adjustable temperature limits, allowing you to set a maximum temperature to prevent scalding. This is particularly useful for vulnerable users, such as children or the elderly. Always refer to the manual for guidance on setting and adjusting these limits. Proper understanding and configuration of these settings are crucial for optimal performance and safety. Regular maintenance, as outlined in the manual, ensures long-term reliability of the temperature control system.
3.2 Adjusting Water Pressure and Flow
The Mira Advance ATL Thermostatic Shower allows for precise adjustment of water pressure and flow to suit your preferences. To optimize performance, ensure the water supply is within the recommended pressure range (typically 1-6 bar). Adjustments can be made using the flow control valve or by fine-tuning the showerhead settings. For low water pressure, consider installing a pump to enhance flow. Always isolate electrical and water supplies before making any adjustments. Regularly check for leaks and ensure connections are secure. Proper adjustment ensures consistent water flow and temperature, enhancing your showering experience. Refer to the manual for detailed guidance on optimizing pressure and flow settings.
3.3 Safety Features and Anti-Scald Protection
The Mira Advance ATL Thermostatic Shower is equipped with advanced safety features, including anti-scald protection, to ensure a safe showering experience. The thermostatic mixing valve regulates water temperature, preventing it from exceeding a safe limit. This feature is particularly beneficial for children and the elderly. The system also includes automatic shut-off in case of water supply issues. Additionally, the shower is designed to monitor water pressure and flow, adjusting temperature dynamically to avoid scalding. LED indicators provide alerts for low pressure or temperature faults, ensuring immediate attention to potential issues. These features collectively enhance safety and user confidence. Regular maintenance ensures optimal performance of these safeguards.
Maintenance and Troubleshooting
Regular checks and descaling are vital for optimal performance. Troubleshooting common issues like low water pressure or error lights is addressed in the manual for quick resolution.
4.1 Regular Maintenance Tips
Regular maintenance ensures the Mira Advance ATL Thermostatic Shower operates efficiently. Cleaning the showerhead and checking for limescale buildup are essential. Descaling every six months prevents mineral accumulation. Inspect and replace worn-out seals or washers to avoid leaks. Ensure the drain pump is clear of debris for proper water drainage. Regularly check the temperature settings and adjust if necessary. Always isolate electrical and water supplies before performing maintenance. Refer to the manual for detailed instructions on descaling and part replacement. Following these tips extends the product’s lifespan and maintains optimal performance.
4.2 Common Issues and Solutions
Common issues with the Mira Advance ATL Thermostatic Shower include low water pressure, temperature fluctuations, and malfunctioning LED lights. For low pressure, check water supply connections and ensure the showerhead is clean. Temperature issues may require resetting the thermostat or checking for limescale buildup. If LED lights malfunction, ensure the electrical supply is stable and connections are secure. Refer to the troubleshooting section for detailed solutions. Always isolate electrical and water supplies before attempting repairs. Consulting the manual or contacting Mira support can resolve persistent problems, ensuring optimal performance and user safety.
4.3 Resetting the Shower and Diagnostic Lights
To reset the Mira Advance ATL Thermostatic Shower, switch off the electrical supply at the mains and wait for a few minutes. Then, restore power and press the stop/start button for 3-5 seconds until the diagnostic lights flash. This process resets the system. Diagnostic lights indicate issues like low water pressure or temperature malfunctions. Flashing patterns correspond to specific problems; consult the manual for details. Always isolate electrical and water supplies before performing maintenance. Resetting and understanding diagnostic lights ensures optimal functionality and safety, addressing common issues effectively.
The Mira Advance ATL Thermostatic Manual is an essential resource for ensuring safe, efficient, and enjoyable use of your shower system. By following the guidelines outlined in this manual, users can navigate installation, operation, and maintenance seamlessly. The detailed troubleshooting section and diagnostic features empower users to address issues promptly, minimizing downtime. Regular maintenance and adherence to safety precautions are key to extending the product’s lifespan. For any unresolved concerns, consulting the manual or contacting Mira Support is recommended. This comprehensive guide ensures a satisfying and hassle-free experience with the Mira Advance ATL Thermostatic Shower.